Download PDF by Zarubin A.N.: A boundary value problem with an involutive shift in the

By Zarubin A.N.

Translated from Differentsialnye Uravneniya, Vol. forty, No. 10, 2004, pp. 1423-1425.

Show description

Read Online or Download A boundary value problem with an involutive shift in the boundary condition PDF

Similar nonfiction_1 books

New PDF release: In the Spirit of Crazy Horse

An "indescribably touching, terribly intelligent" (Los Angeles occasions booklet evaluation) chronicle of a deadly gun-battle among FBI brokers and American Indian circulate activists by means of popular author Peter Matthiessen (1927-2014), writer of the nationwide publication Award-winning The Snow Leopard and the recent novel In Paradise

On a scorching June morning in 1975, a determined shoot-out among FBI brokers and local americans close to Wounded Knee, South Dakota, left an Indian and federal brokers lifeless. 4 individuals of the yank Indian circulation have been indicted on homicide fees, and one, Leonard Peltier, used to be convicted and is now serving consecutive lifestyles sentences in a federal reformatory. in the back of this violent chain of occasions lie problems with nice complexity and profound historic resonance, brilliantly explicated by means of Peter Matthiessen during this arguable booklet. saved off the cabinets for 8 years due to essentially the most protracted and bitterly fought felony instances in publishing background, within the Spirit of loopy Horse finds the Lakota tribe's lengthy fight with the U. S. executive, and makes transparent why the normal Indian proposal of the earth is so vital at a time whilst expanding populations are destroying the valuable assets of our world.

Additional info for A boundary value problem with an involutive shift in the boundary condition

Example text

CT taps can then be based on load and short-circuit considerations for the line without the use of auxiliary cts. 9 Current transformer location It is customary when using dead tank breakers to place cts on both sides of the contacts so that the protection zones will overlap. When live tank breakers are used, the cts are usually freestanding and located on only one side of the breaker. 110-1996 IEEE GUIDE FOR THE APPLICATION OF CURRENT TRANSFORMERS The availability of breaker failure protection can determine which side of the breaker is best for ct location.

If this voltage is less than the voltage setting of the relay, then the relay will not operate. For an internal fault, the cts attempt to force secondary current through the high-impedance differential relay and a relatively high voltage is developed to operate the overvoltage unit. 110-1996 IEEE GUIDE FOR THE APPLICATION OF CURRENT TRANSFORMERS located in the switchyard to minimize the voltage developed to the relay for an external fault and saturated ct. However, ct junction points at the relay location for convenience in cable routing or using existing cables have been successfully applied where the cable run is relatively short and ct and relay requirements are met.

In the case of bus faults, the currents should add up to the line current, which normally is much less than the fault current. If the cores are left with remanence magnetism in them, and the fault has a large dc component, the distance relays could be presented with large error currents. 4 Other types of high-speed protection The effects on these relay systems due to ct saturation can be most serious because of their operating speed, the conÞguration of ct sources, and the need for exactly the same performance at each location of the relaying systems.